文章摘要
Force Analysis of Main Interphone Clamp of Gas Mask Based on Finite Element Simulation
Received:June 08, 2020  Revised:June 08, 2020
DOI:10.12136/j.issn.1000-890X.2021.07.0522
Key Words: gas mask;main interphone;clamp;finite element simulation;force analysis;allowable force;use force
Author NameAffiliationE-mail
WANG Yumin Beihang University wangyumin@buaa.edu.cn 
HAN Minghong* Beihang University hanminghong@buaa.edu.cn 
WANG Gang Shanxi Xinhua Chemical Co. ,Ltd  
QI Jiahao Shanxi Xinhua Chemical Co. ,Ltd  
PAN Gaoyang Shanxi Xinhua Chemical Co. ,Ltd  
Hits: 846
Download times: 435
Abstract:
      The finite element analysis technology was applied to the force analysis of the main interphone clamp of gas mask. When the external force was applied at the upper end and side end of the clamp at an angle of 45°,respectively,the stress states of the clamp under different temperatures and stress conditions were obtained,the maximum allowable forces and maximum use forces of the clamp at different temperatures and positions and their change laws were determined. This study provided a reference for the design of the clamp.
View Full Text   View/Add Comment  Download reader