|
二维码(扫一下试试看!) |
发泡点分析仪热电偶埋设及测试数据重现性的研究 |
Location of Thermocouple of BPA and Repeatability of Test Data |
|
DOI: |
中文关键词: 发泡点分析仪;热电偶埋设位置;重现性 |
英文关键词: blow point analyzer;location of thermocouple;repeatability |
基金项目: |
中图分类号:U463.341;TQ330.7+2 |
Author Name | Affiliation | WANG Ling | Double Coin Group Shanghai Tyre Research Institute Co.Ltd | LI Yue | Double Coin Group Shanghai Tyre Research Institute Co.Ltd | WANG Zhuyi | Hope Technology(Hong Kong)Co.,Ltd | Tosaki Chikao | Ueshima Seisakusho Co.,Ltd |
|
Hits: 662 |
Download times: 350 |
中文摘要: |
研究发泡点分析仪热电偶的埋设及测试数据的重现性。结果表明:相同胶料在不同硫化温度下的温升曲线呈现较为一致的规律性;在相同硫化条件或在不同硫化时间条件下,测温点的温升曲线具有很高的重现性,验证了BPA应用的可靠性。 |
英文摘要: |
The location of thermocouple of blow point analyzer(BPA)and repeatability of the test data were investigated.The results showed that the temperature-rise curves of the same compound at different curing temperature exhibited similar pattern.The repeatability of the temperature-rise curves at the same curing condition or at different curing time was very good,which verified the reliability of BPA in application. |
View Full Text
View/Add Comment Download reader |
Close |