杨柳,姜莹,周伟.,周志诚,蔡淑容,刘国钧,王进.橡胶防老剂BLE-W的入厂检测方法研究[J].轮胎工业,2024,44(12):0764-0767 |
 二维码(扫一下试试看!) |
橡胶防老剂BLE-W的入厂检测方法研究 |
Research on Factory Testing Method for Rubber Antioxidant BLE-W |
投稿时间:2024-06-12 修订日期:2024-06-12 |
DOI: |
中文关键词: 防老剂BLE-W 气相色谱-质谱联用 傅里叶转换红外光谱 热重分析 |
英文关键词: antioxidant BLE-W GC-MS FTIR TG analysis |
基金项目: |
中图分类号: |
|
摘要点击次数: 134 |
全文下载次数: 80 |
中文摘要: |
采用气相色谱-质谱联用、傅里叶转换红外光谱和热重分析方法,建立橡胶防老剂BLE-W的定性定量方法。试验结果证明:所建立的定性方法准确;BLE的定量结果与抽提法的相对偏差小于1%,BLE、碳酸钙和白炭黑含量测试的相对标准偏差(重复6次)分别为0.32%,3.8%和0.38%,均小于4%,精度高,结果满意,可以有效地对入厂的防老剂BLE-W进行质量控制。 |
英文摘要: |
Taking gas chromatography-mass spectrometry(GC-MS),Fourier transform infrared spectroscopy(FTIR) and thermogravimetric(TG) analysis method,a qualitative and quantitative method for rubber antioxidant BLE-W was established.The test results showed that the established qualitative method was accurate.The relatively deviation between quantitative results of BLE and the extraction method was below 1%.The relative standard deviations(repeated 6 times) of BLE,calcium carbonate,and white carbon black content tests were 0.32%,3.8%,and 0.38%,respectively,all less than 4%.The accuracy was high and the results were satisfactory,which could effectively control the quality of the incoming antioxidant BLE-W. |
|
查看全文
查看/发表评论 下载PDF阅读器 |